If so it indicates there is a leak in the vent cap.
Bathroom exhaust fan leaking warm air from attic.
This can be the nails the sheathing the rafters and more.
If you have taken the proper steps to remove excess humid air from your home and you re still having condensation issues it might be time to check the attic insulation.
The tubing or the ducting of the exhaust fan should be insulated and vented to the outside.
Insulation is responsible for keeping warm air inside your living space and out of the attic where it can lead to condensation.
The bathroom exhaust fan is terminating in the attic.
The warm and moist air from your bathroom goes up and meets the cold air from the attic or outside your home.
Make as short of a run as possible to a vent connector through the roof deck.
Cold air is denser and heavier than warm air and wants to go down not up.
The fan pulls warm moist air from the bathroom and distributes the air to the attic.
This meetup leads to condensation and will drip water back to your bathroom.
On a cold day the moisture in the air will condense on anything below the dew point.
If you are concerned about air flowing through the vent just put a page of a magazine behind the fan grille and lock it in place.
The duct is now cold because the attic is cold.
When the exhaust fan is on the damper should on and vice versa.
The duct should be insulated.
No it s never a good idea to have any exhaust fan in your home dump all that hot moist air in your attic.
Actually depending on the prevailing winds at your site cold air may blow in or warm air may leak out.
However you will be suffering more likely because of the poor insulation.
The ducting of your exhaust fan should be properly insulated.
If not this is the problem and you can solve it insulating around the duct.
Many bath vents can be pulled down an inch or so since they have little clips holding them in place.
Warm moist air from the bathroom condenses on the cool duct and runs down the duct to the fan.
The hot and humid summer air will condense when it hits the pipe made cold by the air conditioning system.
It can cause you a lot of problems with mold and mildew forming on the underside of your rafters and decking as well as getting into your insulation.
This can also happen during the warmer months.
So that s where your attention should be.
If so the pipe gets very cold when the fan is not in use.
This cold pipe can cause the air inside the pipe to go from warm to cold.
Several different ways you can move that hot air to the outside.